Assembly Hall Technical Information

Suggested

PERFORMANCE Get-in Variable

DETAILS: Sound check 5 p.m.

Doors open 7.15 p.m.

Show time 8 p.m.

EQUIPMENT ACCESS: Through slip road (rear of venue), Chapel Road (between Museum and Town Hall)

STAGE DOOR ACCESS: Via back door stage door until main doors open, then via main doors

VEHICLE PARKING: Large car park alongside venue

OVERNIGHT SHORT

STAY PARKING: In the slip road in front of venue (to be clear by 8 a.m.)

STAGE SIZES: Open stage (not proscenium arch)

RIGGING: One ton hoists rear of stage and front of house

POWER AVAILABILITY: Lights 3 phase @ 100 amp per phase Source Main intake ELCB

30MA - 125 Amp Ceeform U.S.R.

Sound 60 amp single phase Source Main intake 60 ELCB 30MA

- 63 Amp Ceeform under D.S.L.

SPOTLIGHTS AND Availability 2 Pani HMI 1202 Followspots, positions rear of balcony -

OPERATORS: either side of control room

HOUSE LIGHTS Push button back stage/control room. Dim time down 7-8 secs.,

CONTROL: up 3 secs.

HOUSE LIGHTING: Celco Gold 96 channels: 2 Thomas par Trusses (48 par cans per truss) one over stage, one over auditorium

HOUSE SOUND: Soundcraft 200 16/4/2, Denon DRM700, 4 Shure 545SD, 4 Shure SM58, 3 EMO DI Boxes, 2 Ohn FS220 Monitor Wedges.

2 Community Wedges. Total FOH output 1 kw. approx. 4 Talkback

to:- Control Room x 2, Spots x 2, Under balcony, Backstage x 2

SHOWER FACILITIES: 1 Unit

DRESSING ROOMS: 4 Unisex Dressing rooms, Basins hot and cold water and 13 amp power source

TOILETS: 1 Male, 1 Female